Building service
End suction
Volute pump
Irrigation and agriculture
・Back pull-out structure enables disassebly and inspection without removal of suction and discharge piping.
・High efficiency across a wide range of capacity.
・Can be used for suction pressure up to 7kgf/cm2.
・Quiet operation.
・Conforms JIMS and ISO2868 (excluding some models)
Standard | Optional | ||
Liquid | Clear water 0 to 80°C | ||
Max. suction pressure | 0.4MPa (4kgf/cm2) | 0.41 to 0.7MPa (4.1 to 7.1kgf/cm2) | |
Max. working pressure | 1.37MPa (14kgf/cm2) | ||
Construction | Impeller | Enclosed | Self flushing (negative suction) |
Shaft steal | Glank packing | External flushing (81 to 110°C) | |
Bearing | Sealed ball bearing (Oil-bath) | Casing with drain valve | |
Flange | JIS 10K normal type FF | ||
Materials | Casing | FC250 | Impeller: CAC406 (FC200 model) or SCS13 (FC400 model) Shaft: SUS420J1 or SUS304 Shaft sleeve: SUS304 |
Impeller | FC200 or FC400 | ||
Shaft | S35C or SCM440 | ||
Shaft sleeve | SUS420J1 | ||
Motor |
Three phase, 2 pole or 4 pole
(For the available voltage, please
refer to the attached “Voltage list”)
TEFC Indoor type : 0.4 to 55kW
ODP type : 72 to 250kW
|
TEFC Outdoor type | |
Location | Indoor | ||
Other | Special common base |