Impeller changes and other changes at the level of impeller cuts are possible. If large changes are to be made, it will be necessary to also change the motor and other components. Please inform a Sales Representative of EBARA of the equipment serial number, model, and desired operating points. We will confirm the details of the conditions and offer a proposal.
Rotating, but water does not come out. Discharge quantity is not enogh to specified capacity.
Over load (Overcurrent) occurs.
Excessive water leakage from stuffing box
Electric motor does not work well with noise.
Water comes out at first, but it doesn't come out soon.