Possible causes | Recommended action |
Obstacle is hitting the float. | Clear the obstacle. |
Power failed. | Contact the electric power company and take measures. |
Unbalanced power supply voltage. | Contact the electric power company and take measures. |
Large voltage drop | Contact the electric power company and take measures. |
Open phase | Inspection of wiring and magnet switch |
Defective power circuit connection | Checking the Power circuit |
Incorrect wiring of control circuit | Wire correctly |
Fuse is blown. | Replace the fuse. |
Defective magnet switch | Replace the magnet switch. |
Malfunction or failure of level switch. | Repair or replace the level switch. |
Short circuit breaker is turned actuation. | Repair short circuit section. |
Pump is clogged. | Remove the foreign objects from the pump. |
Electric motor burned | Repair or replace the motor. |
Damaged electric motor bearing | Repair or replace the motor. |
Mechanical Seal Sticking | Replace the mechanical seal. |
Over load (Overcurrent) occurs.
Pump stops after working a while.